Section GENERAL 1. Scope a. This technical manual contains a descrip- tion of Control Unit C-292(*)/TRA-7 (fig. 1) and its operating controls, a chapter on theory of operation, and instructions for field maintenance and repair of the…Historic122 pagesComms Signal
Covers veterinary administration, including the classification, identification, preparation, and rendition of veterinary reports and returns pertaining to sick and wounded animals, to maintain a continuous veterinary history of each animal…Historic73 pagesMedical TCCC
Section I. GENERAL 1-1. This manual provides crew operating and maintenance instructions for the M163, self-propelled Vulcan system. Use it to maintain your proficiency, and keep your M163 in peak condition. A look at the table of contents…Historic347 pagesSustainment
Carbon monoxide is without color or smell, but can cause death. Breathing air with carbon monoxide produces symptoms of headache, dizziness, loss of muscular control, a sleepy feeling, and coma. Brain damage or death can result from heavy…Archive851 pagesSustainment
Google This is a digital copy of a book that was preserved for generations on library shelves before it was carefully scanned by Google as part of a project to make the world's books discoverable online. It has survived long enough for the…Archive169 pagesComms Signal
This publication is prepared as a solid waste management planning guide for Defense Department personnel who are responsible for waste disposal. THE principles prescribed conform to requirements of the Resource Conservation and Recovery…Archive282 pagesEngineering
Be careful when working on the power supply circuits, the 115-volt ac line connections, or the 240-volt plate circuits in Receiver, Radio R-390(*)/URR. Turn off power when working on the transmitting antenna or the transmitting antenna…Historic62 pagesComms Signal
Take particular heed to specific cautions and warnings throughout this manual. HIGH VOLTAGE is used in the operation of this equipment. DEATH or severe burns may result if personnel fail to observe safety precautions. Do not operate this…Historic168 pagesEngineering
Operator's, organizational, direct support, and general support maintenance manual for Power Supply PP-6224B/U, covering equipment description, operation instructions, operator PMCS, and maintenance procedures.Archive132 pagesComms Signal
This manual is for your use in operating and maintaining the Tactical Water Distribution Equipment System (TWDS) Set 10-Mile Segment models 06794-0183-81 (NSN 4320-01-122-3547), 110-00-0000 (NSN 4320-01168-0591), 919 (NSN 4320-01-0590),…Archive314 pagesSustainment
Hand receipt manual covering the components of end item (COEI), basic issue items (BII), and additional authorization list (AAL) for the M915 series trucks: M915 line haul tractor, M916 LET and M920 MET tractors, and the M917/M918/M919…Archive17 pagesSustainment
TM 11—5820—890-—20-2 A lithium-sulfur dioxide (Li-SO2) battery used with Battery Box, CY-8523A/PRC contains pressurized sulfur dioxide (SO2) gas. The gas is toxic, and the battery MUST NOT be abused in any way which may cause the battery…Archive452 pagesComms Signal
TM 5-1940-277-10 TM 1940-10/1 Change 3 a SERIOUS INJURY OR DEATH may result if personnel fail to observe the following safety precautions. Batteries give off explosive hydrogen gas. Be careful making connections. Do not smoke when…Archive199 pagesEngineering
Hand receipt covering the components of end item (COEI), basic issue items (BII), and additional authorization list (AAL) for the M911 commercial heavy equipment transporter truck tractor.Archive25 pagesSustainment
PART ONE INTRODUCTION 1. GENERAL. a. Purpose. The echo box (fig. 1) is a resonant-cavity device designed to simplify the tuning and checking of radar equipment as follows: (1) It provides an artificial or "phantom" target which may be used…Historic41 pagesComms Signal
Carbon monoxide/dioxide gas is not visible and it has no smell, but it can kill you. Breathing air with carbon monoxide/dioxide produces symptoms of headache, dizziness, loss of muscular control, a sleepy feeling, and coma. Brain damage or…Archive369 pagesSustainment
The following abbreviations are found Abbreviation Explanation in the lists: OO Abbreviation Explanation a weoad u/w used with assy assembly w/ with pl jouble wo/ without dia diameter ea each d. Authorization documents are as follows: ft…Archive31 pagesSustainment
Hand receipt manual providing an overprinted DA Form 2062 listing the Components of End Item (COEI), Basic Issue Items (BII), and Additional Authorization List (AAL) items related to the M901 Improved TOW Vehicle.Archive27 pagesSustainment
Rotate the lock knobs of the boresight mount assembly forward (toward objective lens) until they come to a stop on the pins on the assembly. c. Slide the boresight mount assembly onto the guide rail of the M60 adapter assembly from the…Archive54 pagesMarksmanship Weapons
INTRODUCTION/SAFETY l-1. Purpose This manual contains a generalized overview of the fundamentals of transformer theory and operation. The transformer is one of the most reliable pieces of electrical distribution equipment (see figure l-l).…Archive62 pagesEngineering
This publication provides an overprinted DA Form 2062 (Hand Receipt) which lists the contents of Components of End Item (COEI), Basic Issue Items (BII), and Additional Authorization List (AAL) items related to the Palletized Load System…Archive25 pagesSustainment
TM 9-2320-387-10-HR 1-1 Section I. INTRODUCTION 1. SCOPE. This publication provides an overprinted DA Form 2062 (Hand Receipt) which lists the contents of Components of End Item (COEI), Basic Issue Items (BII), and Additional Authorization…Archive25 pagesSustainment
TM 5-822-9/AFM 88-6, Chap.10 2 proper conditions are provided as described herein. Generally pavement repairs with epoxy materials shall not be initiated unless the air and pavement temperatures are above 40 degrees F and rising. Class A…Archive15 pagesEngineering
C 1, TM 11-5820—203-15 appropriate telephone terminal (B, fig. 1-2). b. The letter V in the nomenclature (AN/ MRU-54(V)) indicates that the radio equip- ment used in the shelter is variable and is to be determined by the operating…Historic116 pagesComms Signal
TM 9--2350--292--10--HR 1 Section I. INTRODUCTION 1. SCOPE. This publication provides an overprinted DA Form 2062 (Hand Receipt) which lists the contents of Components of End Item (COEI), Basic Issue Items (BII), and Additional…Archive41 pagesSustainment
ARMY TM 9-1005-249-23&P AIR FORCE TO 11W3-5-5-24 COAST GUARD COMDTINST M8370.9 HOW TO USE THIS MANUAL Read this manual carefully before performing required maintenance. This manual will be referred to for Inspection/Maintenance and Repair…Archive233 pagesMarksmanship Weapons
TM 9-2320-366-10-HR l. SEC (column d). The Controlled Inventory Item Code (formerly SEC code) is entered here. This is a oneposition code which indicates the security classification, security risks, or pilferage controls required for…Archive37 pagesSustainment
TM 9-2320-280-10-HR 1-1 Section I. INTRODUCTION 1. SCOPE. This publication provides an overprinted DA Form 2062 (Hand Receipt) which lists the contents of Components of End Item (COEI), Basic Issue Items (BII), and Additional Authorization…Archive29 pagesSustainment
Start With The Right Holster
Get 10% off your first T.REX holster, access to behind the scenes content, exclusive articles, and product updates delivered to your inbox.